Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Error Code PH91: Low temperature protection of evaporator (Heat Pump)

Updated · by Aurora Star Tech Inc.

Viessmann error code PH91 on a heat pump means: Low temperature protection of evaporator. It is also called Viessmann diagnostic code PH91.

Medium severityHeat PumpVitocal 100-S · DLCURA

Homeowner? What Viessmann code PH91 means for you

Check, then call Your heat pump is reporting: Low temperature protection of evaporator. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code PH91 mean?

The evaporator temperature is too low and protection has tripped.

Applies to: Outdoor unit sizes 18K to 60K

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code PH91

Show all 22 models

06AAK09AAK12AAJ12AAK18AAK24AAK30AAKDLCLRCQ36AA3DLCLRCQ48AA3DLCLRCQ58AA3DLCURAQ18AA3DLCURAQ18AB3DLCURAQ24AA3DLCURAQ24AB3DLCURAQ30AA3DLCURAQ30AB3DLCURAQ36AA3DLCURAQ36AB3DLCURAQ48AA3DLCURAQ48AB3DLCURAQ60AA3DLCURAQ60AB3

Other Viessmann Heat Pump codes

CodeMeaning
PC 46Compressor speed out of control
PC46Compressor speed out of control
PC 49Compressor overcurrent failure
PC49Compressor overcurrent failure
PH(xx)Indoor unit error code PH(xx)
PH90High temperature protection of evaporator
PL(xx)Indoor unit error code PL(xx)
Power LEDPower indicator light
Press. SensorSystem pressure sensor error (indoor unit)
Room Temp.Room temperature sensor error
Temp. HC1Circuit 1 temperature sensor error
Temp. HC2Circuit 2 temperature sensor error

All Viessmann Heat Pump error codes →

Viessmann code PH91: homeowner questions

What does Viessmann code PH91 mean?

Low temperature protection of evaporator. The evaporator temperature is too low and protection has tripped.

Is it safe to keep using my heat pump with code PH91?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Viessmann code PH91 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code PH91 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code PH91 near me?

Aurora Star Tech Inc. repairs Viessmann heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: DLCURA installation instructions, p. 20. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977