Viessmann Error Code PC 40: Communication error between outdoor main PCB and IPM board (Heat Pump)

Updated · by Aurora Star Tech Inc.

Viessmann error code PC 40 on a heat pump means: Communication error between outdoor main PCB and IPM board. It is also called Viessmann diagnostic code PC 40.

High severityHeat PumpVitocal 100-S

Homeowner? What Viessmann code PC 40 means for you

Call a technician Your heat pump is reporting: Communication error between outdoor main PCB and IPM board. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code PC 40 mean?

The main PCB cannot detect the IPM board.

Applies to: DLCLRC outdoor unit

Common causes of Viessmann code PC 40

  • No LED lit on the IPM board
  • Faulty or loose signal wire between IPM board and main board
  • Faulty IPM board

A technician checks these and 2 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code PC 40

Show all 22 models

06AAK09AAK12AAJ12AAK18AAK24AAK30AAKDLCLRCQ36AA3DLCLRCQ48AA3DLCLRCQ58AA3DLCURAQ18AA3DLCURAQ18AB3DLCURAQ24AA3DLCURAQ24AB3DLCURAQ30AA3DLCURAQ30AB3DLCURAQ36AA3DLCURAQ36AB3DLCURAQ48AA3DLCURAQ48AB3DLCURAQ60AA3DLCURAQ60AB3

Other Viessmann Heat Pump codes

CodeMeaning
PC 12Outdoor unit main board DC bus high voltage protection
PC12Main control board DC bus high voltage protection / 341 MCE error
PC 30High pressure protection
PC30System high pressure protection
PC 31Low pressure protection
PC31System low pressure protection
PC40Communication error between outdoor main chip and compressor driven chip
PC 41Outdoor compressor current sampling circuit failure
PC42Compressor start failure
PC 43Outdoor compressor lack phase protection
PC43Outdoor compressor lack phase protection
PC 44Outdoor unit zero speed protection

All Viessmann Heat Pump error codes →

Viessmann code PC 40: homeowner questions

What does Viessmann code PC 40 mean?

Communication error between outdoor main PCB and IPM board. The main PCB cannot detect the IPM board.

Is it safe to keep using my heat pump with code PC 40?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Viessmann code PC 40 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code PC 40 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code PC 40 near me?

Aurora Star Tech Inc. repairs Viessmann heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: DLCLRC Service Manual, p. 34. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.