Viessmann Error Code PC 30: High pressure protection (Heat Pump)

Updated · by Aurora Star Tech Inc.

Viessmann error code PC 30 on a heat pump means: High pressure protection. It is also called Viessmann diagnostic code PC 30.

High severityHeat PumpVitocal 100-S

Homeowner? What Viessmann code PC 30 means for you

Call a technician Your heat pump is reporting: High pressure protection. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code PC 30 mean?

The outdoor pressure switch shuts the system down when high pressure rises above 4.4 MPa.

Applies to: DLCLRC outdoor unit

Common causes of Viessmann code PC 30

  • Faulty or incorrectly wired high pressure switch or main control board connection
  • Broken high pressure protector
  • Outdoor ambient above 50°C

A technician checks these and 4 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code PC 30

Show all 22 models

06AAK09AAK12AAJ12AAK18AAK24AAK30AAKDLCLRCQ36AA3DLCLRCQ48AA3DLCLRCQ58AA3DLCURAQ18AA3DLCURAQ18AB3DLCURAQ24AA3DLCURAQ24AB3DLCURAQ30AA3DLCURAQ30AB3DLCURAQ36AA3DLCURAQ36AB3DLCURAQ48AA3DLCURAQ48AB3DLCURAQ60AA3DLCURAQ60AB3

Other Viessmann Heat Pump codes

CodeMeaning
PC10Outdoor unit low AC voltage protection
PC 10/11/12Quick maintenance error code
PC 11Outdoor unit main board DC bus high voltage protection
PC11Main control board DC bus high voltage protection
PC 12Outdoor unit main board DC bus high voltage protection
PC12Main control board DC bus high voltage protection / 341 MCE error
PC30System high pressure protection
PC 31Low pressure protection
PC31System low pressure protection
PC 40Communication error between outdoor main PCB and IPM board
PC40Communication error between outdoor main chip and compressor driven chip
PC 41Outdoor compressor current sampling circuit failure

All Viessmann Heat Pump error codes →

Viessmann code PC 30: homeowner questions

What does Viessmann code PC 30 mean?

High pressure protection. The outdoor pressure switch shuts the system down when high pressure rises above 4.4 MPa.

Is it safe to keep using my heat pump with code PC 30?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Viessmann code PC 30 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code PC 30 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code PC 30 near me?

Aurora Star Tech Inc. repairs Viessmann heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: DLCLRC Service Manual, p. 33. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.