Viessmann Error Code P5: Indoor units mode conflict (multi-outdoor match) (Heat Pump)

Updated · by Aurora Star Tech Inc.

Viessmann error code P5 on a heat pump means: Indoor units mode conflict (multi-outdoor match). It is also called Viessmann diagnostic code P5.

Low severityHeat PumpDLFSAB · DLFLAB

Homeowner? What Viessmann code P5 means for you

Usually minor Your heat pump is reporting: Indoor units mode conflict (multi-outdoor match). This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code P5 mean?

Indoor units cannot run COOLING and HEATING at the same time. HEATING has priority. If one unit is in COOLING or FAN while another is set to HEATING, the cooling/fan unit turns off or goes to standby while the heating unit keeps running. See the mode conflict table.

Applies to: Multiple indoor units on one outdoor unit

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Viessmann Heat Pump codes

CodeMeaning
Low PressureLow heating medium pressure
LUPLow under pressure
NSUNot set up
Outlet Temp.Outlet temperature sensor error
Outside Temp.Outside temperature sensor error
P(x)Indoor unit error code P(x)
PC(xx)Indoor unit error code PC(xx)
PC 0AHigh temperature protection of condenser
PC0AHigh temperature protection of condenser
PC 0FPFC module protection
PC0FPFC module protection
PC 0LLow ambient temperature protection

All Viessmann Heat Pump error codes →

Viessmann code P5: homeowner questions

What does Viessmann code P5 mean?

Indoor units mode conflict (multi-outdoor match). Indoor units cannot run COOLING and HEATING at the same time. HEATING has priority. If one unit is in COOLING or FAN while another is set to HEATING, the cooling/fan unit turns off or goes to standby while the heating unit keeps running.…

Is it safe to keep using my heat pump with code P5?

Usually yes. Code P5 is normally minor, but if it keeps coming back have it checked.

Can I reset Viessmann code P5 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code P5 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code P5 near me?

Aurora Star Tech Inc. repairs Viessmann heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: DLFSAB and DLFLAB Service Manual, p. 34. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977