Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Error Code FL 09: Indoor and outdoor unit mismatch (Heat Pump)

Updated · by Aurora Star Tech Inc.

Viessmann error code FL 09 on a heat pump means: Indoor and outdoor unit mismatch. It is also called Viessmann diagnostic code FL 09.

High severityHeat PumpVitocal 100-S

Homeowner? What Viessmann code FL 09 means for you

Call a technician Your heat pump is reporting: Indoor and outdoor unit mismatch. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code FL 09 mean?

The indoor and outdoor units are not a matching pair, and the LED shows this code.

Applies to: Indoor and outdoor units

Common causes of Viessmann code FL 09

  • Indoor and outdoor units are not compatible
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code FL 09

Show all 22 models

06AAK09AAK12AAJ12AAK18AAK24AAK30AAKDLCLRCQ36AA3DLCLRCQ48AA3DLCLRCQ58AA3DLCURAQ18AA3DLCURAQ18AB3DLCURAQ24AA3DLCURAQ24AB3DLCURAQ30AA3DLCURAQ30AB3DLCURAQ36AA3DLCURAQ36AB3DLCURAQ48AA3DLCURAQ48AB3DLCURAQ60AA3DLCURAQ60AB3

Other Viessmann Heat Pump codes

CodeMeaning
EL01Indoor and outdoor unit communication error
EL 16Communication malfunction between adapter board and outdoor main board
EL16Communication fault between outdoor main board and transit board
F(x)Indoor unit error code F(x)
FCFC display (normal)
FH 07Communication fault between indoor unit and auto-lifting panel
FrEFreeze protection active
GASA2L gas leak
Heat Pump ModuleHeat pump error (outdoor unit)
HICompressor high speed
HOPHigh over pressure
HP Inlet Temp.Outdoor unit inlet temperature sensor error

All Viessmann Heat Pump error codes →

Viessmann code FL 09: homeowner questions

What does Viessmann code FL 09 mean?

Indoor and outdoor unit mismatch. The indoor and outdoor units are not a matching pair, and the LED shows this code.

Is it safe to keep using my heat pump with code FL 09?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Viessmann code FL 09 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code FL 09 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code FL 09 near me?

Aurora Star Tech Inc. repairs Viessmann heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Viessmann DLCURA service manual, p. 49. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service