Viessmann Error Code PC08: Current overload protection (Heat Pump)

Updated · by Aurora Star Tech Inc.

Viessmann error code PC08 on a heat pump means: Current overload protection. It is also called Viessmann diagnostic code PC08.

High severityHeat PumpDLFSHC · Vitocal IND-H

Homeowner? What Viessmann code PC08 means for you

Call a technician Your heat pump is reporting: Current overload protection. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code PC08 mean?

An abnormal current rise is detected by the outdoor current detection circuit.

Applies to: Outdoor unit current protection

Common causes of Viessmann code PC08

  • Unstable or abnormal supply voltage
  • Incorrect L and N wiring
  • Faulty reactor

A technician checks these and 4 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Viessmann Heat Pump codes

CodeMeaning
PC 03High or low pressure protection
PC03Low pressure protection
PC 04Inverter compressor drive error
PC04Inverter compressor drive error
PC 06Discharge temperature protection of compressor
PC06Discharge temperature protection of compressor
PC 08Current overload protection
PC 08/44/49Quick maintenance error code
PC 10Outdoor unit low AC voltage protection
PC10Outdoor unit low AC voltage protection
PC 10/11/12Quick maintenance error code
PC 11Outdoor unit main board DC bus high voltage protection

All Viessmann Heat Pump error codes →

Viessmann code PC08: homeowner questions

What does Viessmann code PC08 mean?

Current overload protection. An abnormal current rise is detected by the outdoor current detection circuit.

Is it safe to keep using my heat pump with code PC08?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Viessmann code PC08 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code PC08 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code PC08 near me?

Aurora Star Tech Inc. repairs Viessmann heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: DLFSHC Service Manual, p. 27. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service