Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Error Code Temp. HC2: Circuit 2 temperature sensor error (Heat Pump)

Updated · by Aurora Star Tech Inc.

Viessmann error code Temp. HC2 on a heat pump means: Circuit 2 temperature sensor error. It is also called Viessmann diagnostic code Temp. HC2.

Medium severityHeat PumpVitocal 100-AW

Homeowner? What Viessmann code Temp. HC2 means for you

Check, then call Your heat pump is reporting: Circuit 2 temperature sensor error. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code Temp. HC2 mean?

Sensor for heating circuit 2 has a fault.

Applies to: Vitocal 100-AW AM2V controller

Common causes of Viessmann code Temp. HC2

  • Circuit 2 temperature sensor error
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code Temp. HC2

0200280340430510780340043AM2V 020028AM2V 034043AM2V 051078

Other Viessmann Heat Pump codes

CodeMeaning
PH91Low temperature protection of evaporator
PL(xx)Indoor unit error code PL(xx)
Power LEDPower indicator light
Press. SensorSystem pressure sensor error (indoor unit)
Room Temp.Room temperature sensor error
Temp. HC1Circuit 1 temperature sensor error
Thermal Cut-offFixed high limit tripped (indoor unit)

All Viessmann Heat Pump error codes →

Viessmann code Temp. HC2: homeowner questions

What does Viessmann code Temp. HC2 mean?

Circuit 2 temperature sensor error. Sensor for heating circuit 2 has a fault.

Is it safe to keep using my heat pump with code Temp. HC2?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Viessmann code Temp. HC2 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code Temp. HC2 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code Temp. HC2 near me?

Aurora Star Tech Inc. repairs Viessmann heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Vitocal 100-AW AM2V installation, service and operating instructions, p. 69. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977