Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Error Code Heat Pump Module: Heat pump error (outdoor unit) (Heat Pump)

Updated · by Aurora Star Tech Inc.

Viessmann error code Heat Pump Module on a heat pump means: Heat pump error (outdoor unit). It is also called Viessmann diagnostic code Heat Pump Module.

High severityHeat PumpVitocal 100-AW

Homeowner? What Viessmann code Heat Pump Module means for you

Call a technician Your heat pump is reporting: Heat pump error (outdoor unit). The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code Heat Pump Module mean?

General heat pump fault in the outdoor unit.

Applies to: Outdoor unit (ODU)

Common causes of Viessmann code Heat Pump Module

  • Heat pump error - outdoor unit
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code Heat Pump Module

0200280340430510780340043AM2V 020028AM2V 034043AM2V 051078

Other Viessmann Heat Pump codes

CodeMeaning
F(x)Indoor unit error code F(x)
FCFC display (normal)
FH 07Communication fault between indoor unit and auto-lifting panel
FL 09Indoor and outdoor unit mismatch
FrEFreeze protection active
GASA2L gas leak
HICompressor high speed
HOPHigh over pressure
HP Inlet Temp.Outdoor unit inlet temperature sensor error
HP Low PressureOutdoor unit low refrigerant pressure
HP Outlet Temp.Outdoor unit outlet temperature sensor error
IDU PumpIndoor unit circulation pump error

All Viessmann Heat Pump error codes →

Viessmann code Heat Pump Module: homeowner questions

What does Viessmann code Heat Pump Module mean?

Heat pump error (outdoor unit). General heat pump fault in the outdoor unit.

Is it safe to keep using my heat pump with code Heat Pump Module?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Viessmann code Heat Pump Module myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code Heat Pump Module comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code Heat Pump Module near me?

Aurora Star Tech Inc. repairs Viessmann heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Vitocal 100-AW AM2V installation, service and operating instructions, p. 69. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service