Viessmann Error Code E70: IPM overheat (Heat Pump)

Updated · by Aurora Star Tech Inc.

Viessmann error code E70 on a heat pump means: IPM overheat. It is also called Viessmann diagnostic code E70.

High severityHeat PumpVitocal 100-AW AM2V

Homeowner? What Viessmann code E70 means for you

Call a technician Your heat pump is reporting: IPM overheat. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code E70 mean?

The power module (IPM) on the fan driver board is overheating. Usually the fan is not turning and draws high current, or the thermal grease under the module is insufficient.

Applies to: Outdoor unit

Common causes of Viessmann code E70

  • Fan does not rotate and current is high
  • Too little thermally conductive silicone grease under the module
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Viessmann Heat Pump codes

CodeMeaning
E53Ambient temp failure
E54Suction temp failure
E55Anti-freeze temp failure
E56Coil outlet water temp sensor failure
E59EVI inlet temp failure
E68Hot water temp failure
E71Compressor start failure
E72Compressor overcurrent (manual reset required)
E73Input voltage phase loss
E74IPM current sampling fault
E75Overheat protection of drive board devices
E76Pre-charge failure

All Viessmann Heat Pump error codes →

Viessmann code E70: homeowner questions

What does Viessmann code E70 mean?

IPM overheat. The power module (IPM) on the fan driver board is overheating. Usually the fan is not turning and draws high current, or the thermal grease under the module is insufficient.

Is it safe to keep using my heat pump with code E70?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Viessmann code E70 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code E70 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code E70 near me?

Aurora Star Tech Inc. repairs Viessmann heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Vitocal 100-AW AM2V installation, service and operating instructions, p. 81. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.