Viessmann Error Code E14: High pressure protection (Heat Pump)

Updated · by Aurora Star Tech Inc.

Viessmann error code E14 on a heat pump means: High pressure protection. It is also called Viessmann diagnostic code E14.

High severityHeat PumpVitocal 100-AW

Homeowner? What Viessmann code E14 means for you

Call a technician Your heat pump is reporting: High pressure protection. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code E14 mean?

High refrigerant pressure protection has tripped. Causes include a faulty or wrongly wired high pressure switch, scaled heat exchanger, dirty or blocked fins, poor throttling, high outlet water temperature, or refrigerant overcharge.

Applies to: Vitocal 100-AW AM2V outdoor unit

Common causes of Viessmann code E14

  • High pressure switch damaged or wrongly connected
  • Scaling in the casing or plate heat exchanger
  • Dirty or blocked fins with poor airflow

A technician checks these and 3 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code E14

0200280340430510780340043AM2V 020028AM2V 034043AM2V 051078

Other Viessmann Heat Pump codes

CodeMeaning
DHW Tank Temp.DHW tank temperature sensor error
E(x)Indoor unit error code E(x)
E10Reserved
E11Reserved
E12Heating return temperature sensor failure
E13Heating outlet water temperature sensor failure
E15Reserved
E16Low pressure protection
E17Reserved
E18Water flow protection
E19Electric heating overload protection
E20Exhaust temperature overprotection

All Viessmann Heat Pump error codes →

Viessmann code E14: homeowner questions

What does Viessmann code E14 mean?

High pressure protection. High refrigerant pressure protection has tripped. Causes include a faulty or wrongly wired high pressure switch, scaled heat exchanger, dirty or blocked fins, poor throttling, high outlet water temperature, or refrigerant overcharge.

Is it safe to keep using my heat pump with code E14?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Viessmann code E14 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code E14 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code E14 near me?

Aurora Star Tech Inc. repairs Viessmann heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Vitocal 100-AW AM2V installation, service and operating instructions, p. 70. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.