Viessmann Error Code EC52: Open or short circuit of temperature sensor (outdoor) (Heat Pump)

Updated · by Aurora Star Tech Inc.

Viessmann error code EC52 on a heat pump means: Open or short circuit of temperature sensor (outdoor). It is also called Viessmann diagnostic code EC52.

Medium severityHeat PumpVitocal IND-A

Homeowner? What Viessmann code EC52 means for you

Check, then call Your heat pump is reporting: Open or short circuit of temperature sensor (outdoor). This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code EC52 mean?

The sampling voltage is below 0.06 V or above 4.94 V, so the sensor reading is out of range. Highest priority among the sensor codes.

Applies to: Vitocal IND-A DLFUAA air handler, models 18XAK to 60XAK

Common causes of Viessmann code EC52

  • Open or shorted sensor
  • Poor sensor connection
  • Faulty outdoor PCB
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Viessmann Heat Pump codes

CodeMeaning
EC07Outdoor fan speed outside normal range
EC5CHigh pressure sensor failure
EC50Outdoor temperature sensor error
EC 51Outdoor unit EEPROM parameter error
EC51Outdoor EEPROM parameter error or compressor driven chip EEPROM parameter error
EC 52Condenser coil temperature sensor T3 open or shorted
EC 53Outdoor room temperature sensor T4 open or shorted
EC53Outdoor temperature sensor open or short circuit (T3, T4, TP, T2B, TH)
EC 54Compressor discharge temperature sensor TP open or shorted
EC54Open or short circuit of temperature sensor (outdoor)
EC 55IGBT temperature sensor TH open or shorted
EC55Open or short circuit of temperature sensor (outdoor)

All Viessmann Heat Pump error codes →

Viessmann code EC52: homeowner questions

What does Viessmann code EC52 mean?

Open or short circuit of temperature sensor (outdoor). The sampling voltage is below 0.06 V or above 4.94 V, so the sensor reading is out of range. Highest priority among the sensor codes.

Is it safe to keep using my heat pump with code EC52?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Viessmann code EC52 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code EC52 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code EC52 near me?

Aurora Star Tech Inc. repairs Viessmann heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Viessmann Vitocal IND-A DLFUAA service manual, p. 23. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977