Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Error Code PL(xx): Indoor unit error code PL(xx) (Heat Pump)

Updated · by Aurora Star Tech Inc.

Viessmann error code PL(xx) on a heat pump means: Indoor unit error code PL(xx). It is also called Viessmann diagnostic code PL(xx).

High severityHeat PumpVitocal IND-F

Homeowner? What Viessmann code PL(xx) means for you

Call a technician Your heat pump is reporting: Indoor unit error code PL(xx). The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code PL(xx) mean?

Error code beginning with PL followed by two characters, shown in the indoor unit window display. Specific meaning is not listed in the manual.

Applies to: Indoor unit window display

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Viessmann Heat Pump codes

CodeMeaning
PC46Compressor speed out of control
PC 49Compressor overcurrent failure
PC49Compressor overcurrent failure
PH(xx)Indoor unit error code PH(xx)
PH90High temperature protection of evaporator
PH91Low temperature protection of evaporator
Power LEDPower indicator light
Press. SensorSystem pressure sensor error (indoor unit)
Room Temp.Room temperature sensor error
Temp. HC1Circuit 1 temperature sensor error
Temp. HC2Circuit 2 temperature sensor error
Thermal Cut-offFixed high limit tripped (indoor unit)

All Viessmann Heat Pump error codes →

Viessmann code PL(xx): homeowner questions

What does Viessmann code PL(xx) mean?

Indoor unit error code PL(xx). Error code beginning with PL followed by two characters, shown in the indoor unit window display. Specific meaning is not listed in the manual.

Is it safe to keep using my heat pump with code PL(xx)?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Viessmann code PL(xx) myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code PL(xx) comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code PL(xx) near me?

Aurora Star Tech Inc. repairs Viessmann heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Vitocal IND-F DLFSFBH operating instructions, p. 17. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.