Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Error Code FH 07: Communication fault between indoor unit and auto-lifting panel (Heat Pump)

Updated · by Aurora Star Tech Inc.

Viessmann error code FH 07 on a heat pump means: Communication fault between indoor unit and auto-lifting panel. It is also called Viessmann diagnostic code FH 07.

Medium severityHeat PumpVitocal IND-O

Homeowner? What Viessmann code FH 07 means for you

Check, then call Your heat pump is reporting: Communication fault between indoor unit and auto-lifting panel. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code FH 07 mean?

Operation lamp flashes 15 times, timer lamp off.

Applies to: DLFSOAH09XAK, DLFSOAH18XAK indoor units

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Viessmann Heat Pump codes

CodeMeaning
EL 01Indoor / outdoor unit communication error
EL01Indoor and outdoor unit communication error
EL 16Communication malfunction between adapter board and outdoor main board
EL16Communication fault between outdoor main board and transit board
F(x)Indoor unit error code F(x)
FCFC display (normal)
FL 09Indoor and outdoor unit mismatch
FrEFreeze protection active
GASA2L gas leak
Heat Pump ModuleHeat pump error (outdoor unit)
HICompressor high speed
HOPHigh over pressure

All Viessmann Heat Pump error codes →

Viessmann code FH 07: homeowner questions

What does Viessmann code FH 07 mean?

Communication fault between indoor unit and auto-lifting panel. Operation lamp flashes 15 times, timer lamp off.

Is it safe to keep using my heat pump with code FH 07?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Viessmann code FH 07 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code FH 07 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code FH 07 near me?

Aurora Star Tech Inc. repairs Viessmann heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: DLFSOAH service manual, PDF p. 15. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service