Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Navien Furnace Error Codes

Updated · by Aurora Star Tech Inc.

74 Navien Furnace error codes and diagnostic codes, with causes and troubleshooting steps for each. Select a code, or find your model below.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Navien Furnace error codes list

CodeMeaningSeverity
1 FlashHigh limit switch openMedium
2 FlashesPressure switch open with inducer onMedium
3 FlashesPressure switch closed with inducer offMedium
4 FlashesControl in 1 hour lockoutHigh
5 FlashesL1/Neutral polarity problemHigh
6 FlashesToo many limit trips in one call for heatHigh
7 FlashesPressure switch cycle lockoutHigh
8 FlashesLockout due to too many flame dropoutsHigh
9 FlashesFlash code 9 not usedLow
10 FlashesFlame present with gas valve offCritical
E003 00Ignition failureHigh
E004 0False flameMedium
E012 00Flame loss during combustionHigh
E016 00Heat exchanger overheatingCritical
E030 02Abnormal exhaust gas temperature (lock out)Critical
E031 00Burner overheatingCritical
E046 00Abnormal limit control operation on heat exchangerCritical
E047 01Abnormal exhaust temperature sensor operationMedium
E047 02Abnormal exhaust temperature sensor operationMedium
E109 00Abnormal inducer fan operationMedium
E205 01Abnormal supply water temperature sensor, lower limitMedium
E205 02Abnormal supply water temperature sensor, upper limitMedium
E218 01Abnormal return water temperature sensor, lower limitMedium
E218 02Abnormal return water temperature sensor, upper limitMedium
E238 01Abnormal recirculation pump operationMedium
E238 02Abnormal recirculation pump operationMedium
E302 00Low water levelLow
E311 00Abnormal water level sensorMedium
E351 00Abnormal auto water fillMedium
E360 00Abnormal cover openingMedium
E515 01Abnormal WD-PSS1 statusHigh
E515 02Abnormal WD-PSS2 statusHigh
E515 03Abnormal MGV1 statusHigh
E515 04Abnormal MGV2 statusHigh
E515 09Abnormal fan controlHigh
E515 10Abnormal monitoring device statusHigh
E515 16Abnormal AWS feedbackHigh
E515 24Abnormal leakage inputHigh
E517 00Abnormal DIP switch settingsHigh
E593 00Abnormal front panel keysMedium
E594Abnormal EEPROM operationHigh
E594 00Abnormal EEPROM operationHigh
E615Controller fault (sub codes 01, 03, 04, 05)High
E615 01Abnormal overheat controller feedbackCritical
E615 03Abnormal flame signal inputCritical
E615 04Abnormal ADC reference voltageCritical
E615 05Abnormal MCUCritical
E740Abnormal outdoor temperature sensor (sub codes 01, 02)Medium
E740 01, 02Abnormal outdoor temperature sensor operationMedium
E762Vent pipe not detected by Vent Installation Detector (VID)High
E762 00Improper vent pipe installationMedium
E774External safety device on IN_1 stops the furnaceHigh
E774 00Abnormal external safety system operation 1Medium
E775External safety device on IN_2 stops the furnace (auto reset)Medium
E775 00Abnormal external safety system operation 2Medium
E782Controller to front panel communication errorMedium
E782 00Controller to panel communication abnormalMedium
E786Abnormal front control panel connectionMedium
E786 00Abnormal front control panel connectionMedium
E788Abnormal gas type settingHigh
E788 00Abnormal gas type settingsHigh
E799Leak detected (sensor 00, water level 01)Critical
E799 00Leak detected (sensor)Critical
E799 01Leak detected (water level)Critical
E805Abnormal supply air temperature sensor (sub codes 01, 02)Medium
E810Abnormal circulator operation (inoperable), sub codes 00–09High
E811Abnormal circulator operation (inoperable)High
E818Abnormal return air temperature sensor (sub codes 01, 02)Medium
E822Overcooling of the air conditioning coil (evaporator coil)Medium
E860IAQ replacement alerts (sub codes 01, 02, 03)Low
E890Abnormal circulator communicationHigh
LED FlashingGreen LED flashing, high pressure switch not closedMedium
LED OffRed status LED offHigh
LED ONRed status LED on, normal operationLow

Furnace troubleshooting guides

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair

647-657-2977