Navien Furnace: Extreme cold climate venting
Extreme cold climate venting on a Navien furnace: Requirement for periscope venting where extreme cold is expected.
Applies to: NDF600 series furnaces
Common causes of extreme cold climate venting
- Sustained temperatures of -22 F (-30 C) for 48 hours or more
How to fix extreme cold climate venting: step by step
- Use the periscope vent detail in extreme cold climates where -22 F (-30 C) is sustained for 48 hours or more.
- In windy or hill locations, consider roof venting to improve operation.
- Maximum vent length is based on 30 mph (48 km) winds; where higher gusts are common, shorten the horizontal vent length.
If the unit shows an error code, look it up: Navien Furnace codes
Source: Navien NDF installation and operation manual, p. 26. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.