Navien Furnace: Condensate drain not freezing or draining properly in attic or unconditioned space
Condensate drain not freezing or draining properly in attic or unconditioned space on a Navien furnace: Frozen condensate lines block the drain and shut the furnace down.
Applies to: NPF furnace condensate drain
Common causes of condensate drain not freezing or draining properly in attic or unconditioned space
- Drain line routed through unconditioned or uncontrolled space
- Drain line below freezing temperature
How to fix condensate drain not freezing or draining properly in attic or unconditioned space: step by step
- Do not install condensate drain lines in unconditioned or uncontrolled spaces where temperatures can drop below freezing.
- If the line must pass through a cold space, apply UL listed heat tape rated 5 to 6 W/ft at 120 V.
- Use self-regulating or thermostatically controlled heat tape.
- Route the trap to a field-supplied condensate disposal system.
If the unit shows an error code, look it up: Navien Furnace codes
Source: Navien NPF installation and operation manual, p. 73-75. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.