Furnace: Blowing cold air
Blowing cold air on a furnace: The blower is running, but the air at the registers feels cold. Before opening anything up, confirm whether the burners are actually firing, because a cold-air complaint on a gas furnace is often a heat-call problem rather than a failed part. Gas and line voltage are involved here, so anything past the basic checks belongs to a licensed technician.
Applies to: Gas furnaces
Common causes of blowing cold air
- Thermostat fan switch left on On instead of Auto, so the blower runs between heat cycles
- Burner not lighting, or the control locked out after failed ignition
- Limit or pressure switch open while the blower keeps running
- Gas supply interrupted at the valve, meter or line
How to fix blowing cold air: step by step
- Set the thermostat fan to Auto and call for heat, then listen for the inducer and watch for the burners to light
- Look at the control board LED and compare the flash code to the legend on the door for a lockout or limit fault
- Confirm the gas shut-off is open and that the burners ignite and stay lit; do not force the gas valve or bypass any switch
- Check the condensate trap and the pressure switch tubing for water or blockage on a condensing unit
- Once the burners hold, measure the temperature rise across the furnace and compare it to the range on the rating plate
If the unit shows an error code, look it up: AirQuest Furnace codes Allied Furnace codes Carrier Furnace codes Daikin Furnace codes Goodman Furnace codes ICP Furnace codes KeepRite Furnace codes Lennox Furnace codes Midea Furnace codes Navien Furnace codes Rheem Furnace codes Trane Furnace codes York Furnace codes
Source: General HVAC service practice — verify per model. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.