Navien Furnace: Furnace power connection and grounding

Updated · by Aurora Star Tech Inc.

Furnace power connection and grounding on a Navien furnace: The junction box is in the blower compartment. Connect the house wiring to the furnace leads, and make sure the cabinet is continuously grounded.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Furnace line voltage wiring

How to fix furnace power connection and grounding: step by step

  1. Shut off power at the fuse box or service panel before connecting.
  2. Connect the black wire to L1 (hot).
  3. Connect the white wire to L2 (neutral).
  4. Connect the green wire to ground in the junction box.
  5. Use copper conductors only and quality wire nuts.
  6. Do not use gas piping as a ground.
  7. To move the junction box to the other side, fasten it to the chosen side panel, use only ground screws for the enclosure, and fit the plastic cap to the unused panel.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Furnace codes

Source: Navien NDF installation and operation manual, p. 53 to 54. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.