Navien Furnace: Set the installation altitude on the control panel
Set the installation altitude on the control panel on a Navien furnace: The furnace can be installed up to 10,100 ft. Above 2,000 ft it derates 3% per 1,000 ft. The altitude setting must match the real install location or it can cause injury or a malfunction.
Applies to: NPF700 series furnaces
How to fix set the installation altitude on the control panel: step by step
- Look up the installation elevation using the manufacturer's elevation lookup with the zip or postal code.
- Turn the furnace on and set the altitude on the front control panel (see Setting the Model Details in section 5.11.3.8, p. 121).
If the unit shows an error code, look it up: Navien Furnace codes
More commissioning tips for furnace
Source: Navien NPF Condensing Hydro-furnace installation and operation manual, p. 136. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.