Navien Furnace: Rotating the inducer and mounting pressure switches
Rotating the inducer and mounting pressure switches on a Navien furnace: Rotate the inducer to suit the chosen flue orientation, then reinstall the pressure switches and hoses so condensate cannot reach the sensing hose.
Applies to: Inducer orientation changes and pressure switch mounting
Common causes of rotating the inducer and mounting pressure switches
- Condensate draining into the pressure switch sensing hose, causing erratic operation
- Openings between the blower compartment and the combustion compartment, causing incomplete combustion
How to fix rotating the inducer and mounting pressure switches: step by step
- Loosen the collar clamp and raise the exhaust pipe for clearance if needed.
- Disconnect the inducer wire connection.
- Remove the 4 inducer screws.
- Remove the pressure switch assembly and pressure sensing hoses.
- Remove the inducer.
- Reverse the bands on the rubber drain coupling so the screws are reachable. Do not reverse the coupling itself, and make sure the directional arrow points away from the inducer.
- Remove the plastic cap on the side panel for the vent opening in use, and install a cap on any unused vent opening.
- Reinstall the inducer and pressure switch assembly in the correct orientation. Do not use a power tool.
- Mount the pressure switches above the front manifold drain and keep the sensing hoses above it, cut to length with no sags or traps.
- Rotate the drain coupling so the drain holes point 15 degrees down, and tighten the coupling band to the inducer.
- Complete the venting, mount the exhaust pipe and secure it to the collar.
- Secure or support the vent and intake to floor joists or rafters to prevent sagging and fatigue.
- Make sure the blower compartment is fully sealed from the burner compartment, and check that the combustion door gasket is in good condition.
If the unit shows an error code, look it up: Navien Furnace codes
Source: Navien NDF installation and operation manual, p. 38-39. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.