Navien Error Code E238 02: Abnormal recirculation pump operation (Furnace)
Navien error code E238 02 on a furnace means: Abnormal recirculation pump operation. It is also called Navien diagnostic code E238 02.
Homeowner? What Navien code E238 02 means for you
Check, then call Your furnace is reporting: Abnormal recirculation pump operation. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
- Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
- Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Navien error code E238 02 mean?
The pump is off but water flow is detected by the sensor.
Applies to: NPF Condensing Hydro-furnace
Common causes of Navien code E238 02
- Pump is OFF
- Water flow detected
Other Navien Furnace codes
All Navien Furnace error codes →
Navien code E238 02: homeowner questions
What does Navien code E238 02 mean?
Abnormal recirculation pump operation. The pump is off but water flow is detected by the sensor.
Is it safe to keep using my furnace with code E238 02?
It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.
Can I reset Navien code E238 02 myself?
You can try one reset (power off for 30 seconds, then on). If Navien code E238 02 comes back, the cause is still there and a licensed technician should check it.
Who can fix Navien code E238 02 near me?
Aurora Star Tech Inc. repairs Navien furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean
Troubleshooting guides
- Blower cycles on and off All brands · Furnace
- Blower runs, not enough heat All brands · Furnace
- Blowing cold air All brands · Furnace
- Board shows "flame sensed with no call for heat" All brands · Furnace
- Can't pull oil (distance/lift) All brands · Furnace
- CO in flue / poor combustion numbers All brands · Furnace
- Cold air blast at start / blower never stops All brands · Furnace
- Combustion gas / odour in house, flu-like symptoms All brands · Furnace
Source: NPF Condensing Hydro-furnace installation and operation manual, p. 126. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.