Navien Furnace: Choosing a condensate disposal method
Choosing a condensate disposal method on a Navien furnace: Three disposal options are allowed: direct to an external drain, through a neutralizer then to the drain, or through a condensate pump then to a suitable drain. A pump is used when the drain is far from the furnace or when there is not enough fall for gravity drainage.
Applies to: NPF700 series
Common causes of choosing a condensate disposal method
- Long run between the furnace and an accessible drain
- Insufficient gradient for gravity drainage
How to fix choosing a condensate disposal method: step by step
- Pick direct drain, neutralizer, or pump based on the site.
- If a neutralizer is used, the neutralizing agent must be replaced on a schedule that depends on how much the furnace runs.
- If there is not enough fall, install a drain pump rated for boiler, water heater and furnace condensate.
- Keep the condensate line from freezing or being blocked, or condensate can leak from the drain.
If the unit shows an error code, look it up: Navien Furnace codes
Source: Navien NPF installation and operation manual, p. 40. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.