Navien Furnace: Evaporator coil installation and protecting the hydronic coil
Evaporator coil installation and protecting the hydronic coil on a Navien furnace: Install the coil upstream of the cooling unit and keep fasteners out of the hydronic coil area.
Applies to: NPF700 hydro-furnace upflow, horizontal and downflow models
Common causes of evaporator coil installation and protecting the hydronic coil
- Long screws can puncture the hydronic coil.
- Screws in the main cabinet near the hydronic coil can cause leaks.
How to fix evaporator coil installation and protecting the hydronic coil: step by step
- Install the furnace upstream of the evaporator coil when used together.
- Do not install screws in the main cabinet, especially where the hydronic coil sits.
- Fasten the coil only to the flanges at the supply air opening.
- Use screws 3/4 in (20 mm) or less on top (upflow) or bottom (downflow) of the furnace.
- Keep the 7 in (178 mm) area to avoid clear of screws and punctures on the side, back and top.
If the unit shows an error code, look it up: Navien Furnace codes
Source: Navien NPF installation and operation manual, p. 53-55. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.