Navien Furnace: Non-direct vent (single pipe) back-draft risk
Non-direct vent (single pipe) back-draft risk on a Navien furnace: If the installation location can go into negative pressure, cold air can be drawn back through the heat exchanger, which can freeze it and cause a malfunction. Freezing from back-draft is not covered by the warranty. If there is any doubt about back-draft, use direct venting.
Applies to: Non-direct vent installations
Common causes of non-direct vent (single pipe) back-draft risk
- Negative pressure at the installation location
- Poorly balanced air supply in the home
How to fix non-direct vent (single pipe) back-draft risk: step by step
- Check whether the installation location could go into negative pressure.
- If there is any question, use a direct vent system instead.
- Confirm the non-direct vent clearances on the termination clearance table (p. 68).
- Provide two combustion air openings sized per the make-up air table (p. 67).
If the unit shows an error code, look it up: Navien Furnace codes
Source: Navien NPF installation and operation manual, p. 66-67. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.