Navien Furnace: Installing the combustion air inlet pipe drain
Installing the combustion air inlet pipe drain on a Navien furnace: Where moisture can enter the combustion air inlet pipe, condensation can form and drip inside the furnace. A short horizontal or vertical section of pipe with a condensate trap and drain prevents excess water entering the cabinet.
Applies to: Combustion air inlet pipe condensate
Common causes of installing the combustion air inlet pipe drain
- Excessive moisture entering the combustion air inlet pipe
How to fix installing the combustion air inlet pipe drain: step by step
- Install a short horizontal or vertical pipe section with a condensate trap and drain.
- Build the trap using a tee of the same diameter as the air inlet pipe.
- Connect a condensate drain hose to the trap.
- Only connect this drain to the furnace and evaporator coil condensate drain if both drains empty into an open section of pipe above the drain.
If the unit shows an error code, look it up: Navien Furnace codes
Source: Navien NPF installation and operation manual, p. 69. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.