Navien Furnace: Run the Service Wizard self-check
Run the Service Wizard self-check on a Navien furnace: The Service Wizard runs a self-check of the water fill, combustion fan, water circulation, blower and combustion performance.
Applies to: NPF700 series
How to fix run the service wizard self-check: step by step
- Enter the Installer Menu and select Service Wizard.
- Fill water check: the water tank is filled to maximum level.
- Combustion fan check: the fan runs at minimum and maximum RPM.
- Water circulation check: the water adjustment valve opens and closes and the pump turns on and off.
- Blower check: the blower is run.
- Combustion check: combustion performance is checked.
If the unit shows an error code, look it up: Navien Furnace codes
More service & test modes tips for furnace
Source: Navien NPF installation and operation manual, p. 109. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.