Navien Furnace: Combustion air and contamination checks
Combustion air and contamination checks on a Navien furnace: Improper or insufficient combustion air can expose occupants to combustion products including carbon monoxide. Keep the furnace away from contaminated air sources, and isolate a non-direct vent furnace from contaminated rooms.
Applies to: NPF700 all models
Common causes of combustion air and contamination checks
- Chlorine-based pool chemicals, halogen refrigerants, cleaners, solvents, glues, paint removers and similar substances in the combustion air
- Dust, debris, hair spray or spray detergents near the furnace
How to fix combustion air and contamination checks: step by step
- Verify the combustion air supply is adequate.
- Keep the furnace away from the substances listed in the manual, including permanent wave solutions, chlorinated waxes, de-icing salts, carbon tetrachloride, printing inks, varnishes, hydrochloric acid and antistatic dryer softeners.
- For non-direct vent installs, duct combustion air from a nearby clean room or from outdoors (see section 2.11).
If the unit shows an error code, look it up: Navien Furnace codes
Source: Navien NPF installation and operation manual, p. 26. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.