Navien Furnace: Draining the condensate trap (horizontal models)
Draining the condensate trap (horizontal models) on a Navien furnace: Remove the condensate trap to empty it, then reinstall it securely.
Applies to: NPF700 horizontal models
How to fix draining the condensate trap (horizontal models): step by step
- Turn each knob on the upper front cover counterclockwise, remove the cover, then pull the lower front cover back and out.
- Connect the 3/4 in condensate hose from the installation kit to the drain adapter.
- Turn the drain valve on the drain adapter 90 degrees clockwise, then lift the lever on the pressure relief valve to open it.
- Remove the clip from the overflow hose and the condensate drain hose, then remove the two screws holding the condensate trap and take the trap out of the furnace.
- Drain the condensate water from inside the trap.
- After the trap is empty, fix the trap back to the furnace with its two screws and reattach the clip on the overflow hose and condensate hose.
If the unit shows an error code, look it up: Navien Furnace codes
Source: Navien NPF installation and operation manual, p. 143-144. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.