Navien Error Code LED Off: Red status LED off (Furnace)

Updated · by Aurora Star Tech Inc.

Navien error code LED Off on a furnace means: Red status LED off. It is also called Navien diagnostic code LED Off.

High severityFurnaceNDF

Homeowner? What Navien code LED Off means for you

Call a technician Your furnace is reporting: Red status LED off. The furnace has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Navien error code LED Off mean?

Red status LED (AN1) is off. Either the control has no power or the control hardware has a fault.

Applies to: NDF600 models

Common causes of Navien code LED Off

  • No power to the control
  • Control hardware fault
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Navien Furnace codes

CodeMeaning
E811Abnormal circulator operation (inoperable)
E818Abnormal return air temperature sensor (sub codes 01, 02)
E822Overcooling of the air conditioning coil (evaporator coil)
E860IAQ replacement alerts (sub codes 01, 02, 03)
E890Abnormal circulator communication
LED FlashingGreen LED flashing, high pressure switch not closed
LED ONRed status LED on, normal operation

All Navien Furnace error codes →

Navien code LED Off: homeowner questions

What does Navien code LED Off mean?

Red status LED off. Red status LED (AN1) is off. Either the control has no power or the control hardware has a fault.

Is it safe to keep using my furnace with code LED Off?

It depends on the cause. The furnace has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Navien code LED Off myself?

You can try one reset (power off for 30 seconds, then on). If Navien code LED Off comes back, the cause is still there and a licensed technician should check it.

Who can fix Navien code LED Off near me?

Aurora Star Tech Inc. repairs Navien furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

Troubleshooting guides

Source: Navien NDF installation and operation manual, p. 70. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.