Priming the condensate trap on a Navien furnace: The condensate trap must be full of water before the furnace starts. Priming is done through the vent drain hose at the inducer.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: NDF condensate trap

How to fix priming the condensate trap: step by step

  1. Remove the vent drain hose from the inducer elbow or drain fitting.
  2. Pour about one cup of water down the hose.
  3. Wait for water to run out the condensate trap outlet, which shows the trap is full.
  4. Reconnect the vent drain hose to the inducer elbow or drain fitting.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Furnace codes

More commissioning tips for furnace

Source: Navien NDF Installation and Operation Manual, p. 45. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.