Navien Furnace: Measure inlet gas pressure

Updated · by Aurora Star Tech Inc.

Measure inlet gas pressure on a Navien furnace: Licensed professional only. Furnace must have enough inlet gas pressure to run. Steps 2 to 7 are not on these pages.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: NPF700 hydro-furnace inlet gas pressure check

How to fix measure inlet gas pressure: step by step

  1. Shut off the manual gas valve on the gas supply line.
  2. Loosen the screw shown in the figure and connect a manometer to the pressure port.
  3. Zero the manometer before use.
  4. Reopen the manual gas valve and check all joints for leaks.
  5. Restart the furnace so the MAX setting runs the burner and fan at full capacity.
  6. At maximum firing rate, read the inlet gas pressure and confirm it is within the range for the gas type.
  7. Reinstall the upper front cover, seat it fully against the furnace, and tighten the three knobs clockwise.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Furnace codes

Source: Navien NPF installation and operation manual, p. 49-50. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.