Navien Furnace: Check 24VAC thermostat and output inputs
Check 24VAC thermostat and output inputs on a Navien furnace: The Operation Status view shows whether each thermostat input (W1, W2, Y1, Y2, G, O/B, DEHUM) is active and the state of the HUM, DEHUM and EAC outputs. Some items are hidden depending on parameter settings, so a missing item is not always a fault. The cooling stage item only appears when Heat Only is set to No.
Applies to: NPF700 series
How to fix check 24vac thermostat and output inputs: step by step
- Open the Operation Status Information view from the status menu.
- Check each 24VAC input status against the thermostat call you are testing.
- Check the HUM, DEHUM and EAC output status.
- Press Back to exit.
If the unit shows an error code, look it up: Navien Furnace codes
More service & test modes tips for furnace
Source: Navien NPF installation and operation manual, p. 105. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.