Navien Furnace: Installing the intake and exhaust air collars

Updated · by Aurora Star Tech Inc.

Installing the intake and exhaust air collars on a Navien furnace: Remove the upper front cover and attach the intake and exhaust collars with the VID sensor cable routed through the cabinet. The exhaust collar connector must be connected to the VID sensor connector or the furnace will not run.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: NPF700 all models

How to fix installing the intake and exhaust air collars: step by step

  1. Remove the plastic caps from the intake and exhaust connections.
  2. Turn the three knobs on the upper front cover counterclockwise and remove the cover.
  3. Route the VID sensor cable through the hole, attach the intake and exhaust collars to the duct holes and tighten the screws.
  4. Insert the intake filter at the bottom of the intake air collar.
  5. Connect the exhaust collar connector to the VID sensor connector inside the furnace.
  6. Reinstall the upper front cover, seat it fully and tighten the three knobs clockwise.
  7. Install the condensate trap on the left or right side of the furnace (see section 2.14).
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Furnace codes

Source: Navien NPF installation and operation manual, p. 31. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.