Navien Furnace: Manual water fill

Updated · by Aurora Star Tech Inc.

Manual water fill on a Navien furnace: Fill the water tank by hand when the level is at 1/4 or below. Do this only after the furnace is fully installed and powered on. About 2 gallons (7.5 L) fills it completely.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: NPF700 series

How to fix manual water fill: step by step

  1. Check the water level on the front control panel.
  2. Open the water inlet cover on the lower-front cover.
  3. Remove the water inlet plug.
  4. Pour water in through the inlet. Watch the level on the front panel because the pump circulates water and the level drops during fill, so more water may be needed.
  5. Stop when the level is full. Extra water runs out through the drain line.
  6. Install the water inlet plug and close the water inlet cover.
  7. Make sure the inlet cover is closed. An interlock switch stops the unit from running when it is open.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Furnace codes

More commissioning tips for furnace

Source: Navien NPF installation and operation manual, p. 42. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.