Navien Furnace: Gas piping installation
Gas piping installation on a Navien furnace: Gas piping must follow NFPA 54/ANSI Z223.1 in the US or CAN/CSA-B149.1 and 2 in Canada, plus local codes. The gas pipe into the furnace side panel must be 1/2 in. Schedule 40 black iron through the special rubber grommet.
Applies to: NDF gas connection
How to fix gas piping installation: step by step
- Install gas piping per NFPA 54/ANSI Z223.1 (US) or CAN/CSA-B149.1 and 2 (Canada) and local codes.
- If a flexible connector is allowed, use a new listed connector only. Do not reuse one from another gas appliance.
- Use 1/2 in. Schedule 40 black iron pipe through the side panel.
- Route the pipe through the rubber grommet, which seals around the pipe. Move the plastic cap to the other side panel if the pipe enters from there.
- Install a union between the gas valve and the side panel to ease burner removal for service.
If the unit shows an error code, look it up: Navien Furnace codes
Source: Navien NDF Installation and Operation Manual, p. 47. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.