Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Navien Furnace: Clear error 788 after a propane conversion

Updated · by Aurora Star Tech Inc.

Clear error 788 after a propane conversion on a Navien furnace: After changing DIP switch 1 to propane, the furnace shows error 788 until the gas type is confirmed.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: NPF700 series furnaces

How to fix clear error 788 after a propane conversion: step by step

  1. With the error displayed, press the Back button to open the Gas Type Check under the Start-Up Wizard.
  2. Set the Gas Type Check option to Propane Gas.
  3. Confirm the gas type shows as changed in the Gas Conversion Kit Required option; the error clears and the furnace runs.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Furnace codes

More settings shortcuts tips for furnace

Source: Navien NPF Condensing Hydro-furnace installation and operation manual, p. 135. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair

647-657-2977