Navien Furnace: Clear error 788 after a propane conversion
Clear error 788 after a propane conversion on a Navien furnace: After changing DIP switch 1 to propane, the furnace shows error 788 until the gas type is confirmed.
Applies to: NPF700 series furnaces
How to fix clear error 788 after a propane conversion: step by step
- With the error displayed, press the Back button to open the Gas Type Check under the Start-Up Wizard.
- Set the Gas Type Check option to Propane Gas.
- Confirm the gas type shows as changed in the Gas Conversion Kit Required option; the error clears and the furnace runs.
If the unit shows an error code, look it up: Navien Furnace codes
More settings shortcuts tips for furnace
Source: Navien NPF Condensing Hydro-furnace installation and operation manual, p. 135. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.