Navien Furnace: Category IV venting and positive pressure
Category IV venting and positive pressure on a Navien furnace: The NPF is a Category IV appliance with positive pressure in the vent. Use only the specified venting system and install direct vent when possible.
Applies to: NPF direct vent and venting systems
How to fix category iv venting and positive pressure: step by step
- Vent exhaust gases directly outdoors with the recommended materials.
- Do not connect the furnace vent to any other gas appliance vent.
- Each furnace needs its own intake and vent pipes, terminated individually.
- Do not connect the furnace to a chimney flue that serves a solid fuel appliance.
- Use a new vent system if possible; if reusing one, inspect it for punctures, cracks and blockages.
- If a furnace replaces one on an existing vent, check that the remaining appliance vents still meet code and may need re-sizing.
If the unit shows an error code, look it up: Navien Furnace codes
Source: Navien NPF installation and operation manual, p. 59. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.