Navien Furnace: Combustion air source and corrosive atmosphere
Combustion air source and corrosive atmosphere on a Navien furnace: Air for combustion must not come from a corrosive atmosphere. Corrosion-related failures are not covered by warranty.
Applies to: NDF600 series furnaces
How to fix combustion air source and corrosive atmosphere: step by step
- Check the site. Commercial buildings, indoor pools, laundry rooms, hobby or craft rooms and areas near chemical storage usually need outdoor combustion air.
- Make sure combustion air is free of sulphur, fluorine and chlorine (found in aerosols, detergents, bleaches, solvents, paint removers and refrigerants).
- Check local authority bylaws in addition to CAN/CGA-B149 or ANSI Z223.1.
If the unit shows an error code, look it up: Navien Furnace codes
More commissioning tips for furnace
Source: Navien NDF Forced Air Gas Furnace Installation and Operation Manual, p. 21. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.