Navien Furnace: Annual service: furnace operation checks
Annual service: furnace operation checks on a Navien furnace: Checks a technician should run during annual inspection to confirm normal operation.
Applies to: NDF forced air gas furnace
How to fix annual service: furnace operation checks: step by step
- Cycle the furnace and test all safety related controls.
- Confirm the temperature rise falls within the range on the rating plate.
- Confirm burner ignition is smooth and flames are smooth, soft blue, not impinging on the heat exchanger.
- Time the gas meter and/or check manifold pressure to confirm input matches the rating plate.
- Inspect the heat exchanger for corrosion; flue passages must be free of scale or excessive corrosion.
If the unit shows an error code, look it up: Navien Furnace codes
Source: Navien NDF installation and operation manual, p. 90-91. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.