Navien Furnace: LP derate above 2,000 ft

Updated · by Aurora Star Tech Inc.

LP derate above 2,000 ft on a Navien furnace: For LP installations above 2,000 ft, reduce the certified input rating by 4% for every 1,000 ft (305 m) above sea level. Pick orifices from the high altitude table for installs above the certified altitude.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: LP gas at high altitude

How to fix lp derate above 2,000 ft: step by step

  1. Calculate the required input reduction: 4% per 1,000 ft above sea level, starting above 2,000 ft.
  2. Select orifice sizes from Table 6 (Orifice Size for High Altitude Installation).
  3. Confirm the installation altitude before choosing orifices.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Furnace codes

More commissioning tips for furnace

Source: Navien NDF installation and operation manual, p. 49. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.