LP derate above 2,000 ft on a Navien furnace: For LP installations above 2,000 ft, reduce the certified input rating by 4% for every 1,000 ft (305 m) above sea level. Pick orifices from the high altitude table for installs above the certified altitude.
Applies to: LP gas at high altitude
How to fix lp derate above 2,000 ft: step by step
- Calculate the required input reduction: 4% per 1,000 ft above sea level, starting above 2,000 ft.
- Select orifice sizes from Table 6 (Orifice Size for High Altitude Installation).
- Confirm the installation altitude before choosing orifices.
If the unit shows an error code, look it up: Navien Furnace codes
More commissioning tips for furnace
Source: Navien NDF installation and operation manual, p. 49. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.