Navien Furnace: Wiring replacement and grounding
Wiring replacement and grounding on a Navien furnace: Replacement wire must be copper with at least 221°F (105°C) rating. Gas piping and water piping must never be used as ground.
Applies to: NPF furnace wiring and grounding
How to fix wiring replacement and grounding: step by step
- Use only copper conductor replacement wire rated at least 221°F (105°C).
- Connect an earth ground wire from the furnace ground screw in the junction box to the electrical service panel.
- Do not attach the ground wire to gas or water pipes; plastic pipe or dielectric unions can prevent proper grounding.
- Label all wires before disconnecting them when servicing the controls.
- Check operation after any service.
If the unit shows an error code, look it up: Navien Furnace codes
Source: Navien NPF installation and operation manual, p. 77-79. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.