Updated · by Aurora Star Tech Inc.

Wire a dehumidistat to the sub controller on a Navien furnace: Dehumidistat must run on 24 VAC and use a switch that opens when humidity rises. During a combined cooling and dehumidification call the blower runs at about 85% of the desired speed.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: NPF700 Hydro-furnace with optional dehumidistat

How to fix wire a dehumidistat to the sub controller: step by step

  1. Turn off power to the furnace.
  2. Connect the dehumidistat neutral wire (usually white) to the DEH terminal on the sub controller.
  3. Connect the dehumidistat hot wire (usually black) to the R terminal on the sub controller.
  4. Connect the dehumidistat ground wire (usually green) to the ground screw on the junction box, if present.
  5. Restore power and turn on the dehumidification function on the front control panel.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Furnace codes

Source: Navien NPF installation and operation manual, p. 83. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.