Navien Furnace: Gas piping rules for Massachusetts
Gas piping rules for Massachusetts on a Navien furnace: In Massachusetts the product must be installed by a licensed plumber or gas fitter. Flexible connectors may not exceed 36 in (914 mm), lever-type shutoffs must be T-handle type, and copper tubing for gas piping is not allowed.
Applies to: NPF condensing hydro-furnace in Massachusetts
How to fix gas piping rules for massachusetts: step by step
- Confirm a licensed plumber or gas fitter does the installation.
- Keep any flexible gas connector at 36 in (914 mm) or less.
- Use T-handle lever-type gas shutoffs.
- Do not use copper tubing for the gas piping.
If the unit shows an error code, look it up: Navien Furnace codes
More commissioning tips for furnace
Source: Navien NPF installation and operation manual, p. 6. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.