Navien Furnace: Glycol for freeze protection in the hydronic loop

Updated · by Aurora Star Tech Inc.

Glycol for freeze protection in the hydronic loop on a Navien furnace: Propylene glycol may be used up to 30% concentration. Higher concentrations reduce input and can cause noise in the hydronic system. Glycol is injected manually into the water tank (see section 2.8).

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: NPF700 all models

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Furnace codes

More other tips for furnace

Source: Navien NPF installation and operation manual, p. 27. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.