Navien Furnace: Setting the furnace on a level base and combustible surfaces
Setting the furnace on a level base and combustible surfaces on a Navien furnace: The furnace must sit level so condensate drains properly. Do not install it directly on carpet or other combustible material; wood is the only combustible floor material allowed.
Applies to: NPF700 all models
How to fix setting the furnace on a level base and combustible surfaces: step by step
- Set the furnace on a level floor.
- If the floor is damp at times, raise the furnace on a concrete base about 1-1/2 in larger than the furnace base.
- Do not place the furnace on carpet.
- If on a combustible floor, the floor must be wood.
If the unit shows an error code, look it up: Navien Furnace codes
Source: Navien NPF installation and operation manual, p. 26-28. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.