Navien Furnace: Vent location precautions and condensate protection
Vent location precautions and condensate protection on a Navien furnace: Avoid locations where flue condensate, freezing or recirculation can cause damage or problems.
Applies to: NDF600 series furnaces
Common causes of vent location precautions and condensate protection
- Flue gas condensate freezing on walls, soffits or nearby objects
- Recirculation of flue gases into the combustion air intake
- Condensate damaging shrubs, planters or finishes
How to fix vent location precautions and condensate protection: step by step
- Caulk all cracks, seams or joints within a 6 ft (1.8 m) radius of the termination.
- Do not locate the terminal on the side of the building facing prevailing winter winds.
- Do not terminate under a deck unless there is adequate clearance; if piping runs under a deck, insulate it and suspend it so condensate cannot collect and freeze.
- Do not place the terminal where dripping condensate will fall on sidewalks, patios, planters or near windows where fogging or icing can occur.
- Keep the terminal away from shrubs and vegetation.
- Check that adjacent painted surfaces are in good condition, and seal wooden surfaces exposed to flue gases if needed.
- Do not terminate where condensate or vapor could affect regulators, relief valves or other equipment.
If the unit shows an error code, look it up: Navien Furnace codes
Source: Navien NDF installation and operation manual, p. 26, 28, 32. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.