Navien Furnace: Suspended horizontal installation
Suspended horizontal installation on a Navien furnace: A horizontal furnace may be supported from below or suspended. A suspended cradle uses slotted angle iron and threaded rod. The cabinet must not twist or sag.
Applies to: NDF600 series
How to fix suspended horizontal installation: step by step
- Use at least 2 in (51 mm) slotted angle or equivalent.
- Position supports so they do not block burner or blower access.
- Keep the cabinet from twisting or sagging.
If the unit shows an error code, look it up: Navien Furnace codes
More commissioning tips for furnace
Source: Navien NDF installation and operation manual, p. 13 and p. 14. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.