Navien Furnace: Neutralizer media check and replacement
Neutralizer media check and replacement on a Navien furnace: Check the neutralizer media and outlet pH regularly. The manual recommends an annual pH test with test strips or an electronic meter.
Applies to: NPF700 series with neutralizer disposal
How to fix neutralizer media check and replacement: step by step
- Test the pH at the neutralizer outlet once a year.
- Replace the neutralizing media when pH falls below the minimum set by the local water authority.
- If no local minimum is specified, replace the media when pH is below 6.0.
- Get replacement media from the local Navien distributor.
If the unit shows an error code, look it up: Navien Furnace codes
Source: Navien NPF installation and operation manual, p. 41-42. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.