Navien Furnace: Vent slope, support and insulation
Vent slope, support and insulation on a Navien furnace: Horizontal vent runs must drain back to the furnace and be supported and insulated where needed.
Applies to: Horizontal and vertical vent runs
How to fix vent slope, support and insulation: step by step
- Slope horizontal runs down toward the furnace at 1/4 in per foot (2%).
- Support exhaust and intake pipes at least every 4 ft (1.2 m) or as local code requires.
- Insulate vent pipe that runs through unconditioned space to stop condensate freezing.
- Keep the vent run as short and straight as possible and put the furnace close to the termination.
If the unit shows an error code, look it up: Navien Furnace codes
More commissioning tips for furnace
Source: Navien NPF installation and operation manual, p. 60. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.