Navien Furnace: Cooling coil placement with the furnace
Cooling coil placement with the furnace on a Navien furnace: If the furnace is used with a cooling unit, the furnace must go upstream of or in series with the coil. A coil upstream of the furnace causes premature heat exchanger failure. For vertical applications the coil width must be at least the furnace width minus 1 inch. A coil above an upflow furnace may match the furnace width or be one size larger.
Applies to: NPF700 with cooling coil
If the unit shows an error code, look it up: Navien Furnace codes
Source: Navien NPF installation and operation manual, p. 26. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.